7
SNTP
The printer clock can be synchronized with a NTP server clock using the Simple
Network Time Protocol (SNTP). To change the SNTP settings, use the sntp com-
mand. Confirm with the network administrator that the NTP server settings are
correct.
Limitation
SNTP supports the NTP servers running xnptd V3 and V4.
Reference
msh> sntp
NTP Server Address Configuration
You can specify the IP address of the NTP server.
msh> sntp server IP_address
Interval Configuration
You can specify the interval at which the printer synchronizes with the oper-
ator-specified NTP server.
msh> sntp interval polling_time
Note
The factory default setting is 3600 seconds.
You can set the interval from 16 to 16384 seconds.
If you set 0, the printer synchronizes with the NTP server only when you
turn the printer on. After that, the printer does not synchronize with the
NTP server.
Time-zone Configuration
You can specify the time difference between the printer clock and the NTP
server clock.
msh> sntp timezone +/-hour_time
Example: To set the time-zone difference to +8 hours:
msh> sntp timezone +08:00
Note
The time is in 24-hour notation.