Toshiba e-STUDIO351c Copier User Manual


 
e-STUDIO281c/351c/451c ERROR CODE AND SELF-DIAGNOSTIC MODE June 2005 © TOSHIBA TEC
2 - 88
Notes:
1. The digit after the hyphen in “Code” of the following table is a sub code.
2. In “RAM”, the NVRAM of the board in which the data of each code is stored is indicated. “M”
stands for the LGC board, “SYS”, “NIC” and “UTY” stands for the SYS board.
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM Contents
Pro-
cedur
e
200 General Date and time setting ALL -
<13 dig-
its>
- Year/month/date/day/
hour/minute/second
Example:
03 07 0 13 13 27 48
“Day” - “0” is for “Sun-
day”. Proceeds Monday
through Saturday from
“1” to “6”.
5
201 General Destination selection ALL EUR: 0
UC: 1
JPN: 2
<0-3>
M0: EUR
1: UC
2: JPN
3: Other
1
202 User
interface
Counter installed externally ALL 0
<0-4>
M 0: No external counter
1: Coin controller
2: Copy key card
3: Key copy counter
4: Key card for OEM1
1
203 General Line adjustment mode ALL 0
<0-1>
M 0: For factory ship-
ment
1: For line
* Field: “0” must be
selected
1
204 User
interface
Auto-clear timer setting ALL 3
<0-10>
SYS Timer to return the
equipment to the
default settings when
the [START] button is
not pressed after the
function and the mode
are set
0: Not cleared
1 to 10:
Set number x 15
sec.
1
205 User
interface
Auto power save mode
timer setting
ALL 11
<0, 6-15>
SYS Timer to automatically
switch to the energy
saving mode when the
equipment has not
been used
0: Invalid 6: 3min.
7: 4min. 8: 5min.
9: 7min.
10: 10min.
11: 15min.
12: 20min.
13: 30min.
14: 45min.
15: 60min.
1