Toshiba e-STUDIO351c Copier User Manual


 
June 2005 © TOSHIBA TEC e-STUDIO281c/351c/451c ADJUSTMENT
3 - 3
3
Note: Note:
The current sensor voltage (V) shown in (B) automatically changes, gradually approaching the
target value for adjustment reference voltage shown in (A).
In 30 to 60 seconds, the current sensor voltage (V) in (B) is converged. Then the sensor out-
put control value (bit value) corresponding to the initial developer material is displayed in (C).
Note: Note:
Be careful that the values in (A), (B) and (C) vary with humidity.
In case of single-color adjustment, press the [ENTER] button to store the adjustment results
in memory when the control value is displayed. In case of multiple-color adjustment, it is auto-
matically proceeded to the adjustment of next color.
(5) Adjustments for “Y”, “M” and “C” (light sensor control)
In 15 to 45 seconds, the following message will be displayed (The time varies with the num-
ber of colors to be adjusted).
(
B
)
: Current sensor voltage
(
V
)
(
C
)
: Sensor output control value
(
bit value
)
(
A
)
: Target value
(
V
)
for adjustment reference voltage
K: xxxV
K: yyy
K: zzzV
(
B
)
(
C
)
(
A
)
(
B
)
(
C
)
(
A
)
(
B
)
: Current sensor voltage
(
V
)
(
C
)
: No display
(
A
)
: Target value
(
V
)
for adjustment reference voltage
Y:
Y: