Toshiba e-STUDIO351c Copier User Manual


 
June 2005 © TOSHIBA TEC e-STUDIO281c/351c/451c ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 95
2
276 User
interface
Default setting of density
adjustment (Black)
SCN
(black)
0
<0-11>
SYS 0: Automatic density
1: Step -5
2: Step -4
3: Step -3
4: Step -2
5: Step -1
6: Step 0 (center)
7: Step +1
8: Step +2
9: Step +3
10: Step +4
11: Step +5
(1 to 11: Manual den-
sity)
1
277 User
interface
Default setting of back-
ground adjustment
(Full Color)
SCN
(color)
3
<1-5>
SYS 1: Step -2
2: Step -1
3: Step 0 (center)
4: Step +1
5: Step +2
1
278 User
interface
Default setting of color
mode
SCN 0
<0-4>
SYS 0: Black
1: Gray Scale
2: Unused
3: Full Color
4: Auto Color
1
279 User
interface
Default setting of resolution
(Full Color)
SCN
(color)
2
<0-3>
SYS 0: 100 dpi
1: 150 dpi
2: 200 dpi
3: 300dpi
1
280 User
interface
Default setting of resolution
(Gray Scale)
SCN
(black)
2
<0-4>
SYS 0: 100 dpi
1: 150 dpi
2: 200 dpi
3: 300dpi
4: 400 dpi
1
281 User
interface
Default setting of resolution
(Black)
SCN
(black)
1
<0-4>
SYS 0: 150 dpi
1: 200 dpi
2: 300 dpi
3: 400dpi
4: 600 dpi
1
282 User
interface
Default setting of original
mode (Full Color)
SCN
(color)
0
<0-2>
SYS 0: Text
1: Photo
2: Printed Image
1
283 User
interface
Default setting of original
mode (Black)
SCN
(black)
0
<0-2>
SYS 0: Text
1: Text/Photo
2: Photo
1
284 User
interface
Default setting of scanning
mode
SCN 0
<0-2>
SYS 0: Single
1: Book
2: Tablet
1
285 User
interface
Default setting of rotation
mode
SCN 0
<0-3>
SYS 0: 0 degree
1: 90 degrees
2: 180 degrees
3: 270 degrees
1
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM Contents
Pro-
cedur
e