440-0 Fuser Pre-running time for first
printing
(Plain paper/Low tempera-
ture environment)
ALL
(black)
12
<0-16>
M 0: Invalid 1: 0 sec.
2: 2 sec. 3: 3 sec.
4: 4 sec. 5: 5 sec.
6: 6 sec. 7: 7 sec.
8: 8 sec. 9: 10 sec.
10: 12 sec.
11: 14 sec.
12: 16 sec.
13: 18 sec.
14: 20 sec.
15: 25 sec.
16: 30 sec.
4
440-1 ALL
(color)
0
<0-16>
M4
441-0 Fuser Pre-running time for first
printing (Thick paper 1)
ALL
(black)
9
<0-16>
M 0: Invalid 1: 0 sec.
2: 2 sec. 3: 3 sec.
4: 4 sec. 5: 5 sec.
6: 6 sec. 7: 7 sec.
8: 8 sec. 9: 10 sec.
10: 12 sec.
11: 14 sec.
12: 16 sec.
13: 18 sec.
14: 20 sec.
15: 25 sec.
16: 30 sec.
4
441-1 ALL
(color)
5
<0-16>
M4
449 Paper
feeding
Switching for incorrect
paper size jam detection
ALL 0
<0-1>
M 0: Enabled
1: Disabled
1
458 Fuser Threshold for warming-up
temperature(Low-tempera-
ture environment)
ALL 6
<0-11>
M0:0°C 1: 5°C
2: 9°C 3: 10°C
4: 12°C 5: 14°C
6: 15°C 7: 16°C
8: 17°C 9: 18°C
10: 19°C 11: 20°C
1
459 Fuser Warming-up time(Low-tem-
perature environment)
ALL 7
<0-11>
M 0: No warming-up
1: 30 sec. 2: 40 sec.
3: 50 sec. 4: 60 sec.
5: 70 sec. 6: 80 sec.
7: 90 sec.
8: 100 sec.
9: 120 sec.
10: 180 sec.
11: 300 sec.
1
460 Fuser Threshold of temperature
for pre-running time for first
printing(Low-temperature
environment)
ALL 9
<0-11>
M 0: 0°C 1: 5°C
2: 9°C 3: 10°C
4: 12°C 5: 14°C
6: 15°C 7: 16°C
8: 17°C 9: 18°C
10: 19°C 11: 20°C
1
461 Fuser Pre-running time for first
printing(Plain paper/Low-
temperature environment)
ALL 8
<0-11>
M 0: Invalid (always)
1: 0 min. 2: 0.5 min.
3: 1 min. 4: 2 min.
5: 3 min. 6: 5 min.
7: 7 min. 8: 10 min.
9: 15 min. 10: 30 min.
11: 60 min.
1
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM Contents
Pro-
cedur
e