Toshiba e-STUDIO351c Copier User Manual


 
e-STUDIO281c/351c/451c ERROR CODE AND SELF-DIAGNOSTIC MODE June 2005 © TOSHIBA TEC
2 - 140
858-0 Develop-
ment
Color toner
forced supply
level display
YALL
(color)
0
<0-1>
M Becomes “1” when the
toner density decreases
and it is judged forced
toner supply is needed.
0: Normal level
1: Forced supply level
14
858-1 M ALL
(color)
0
<0-1>
M14
858-2 C ALL
(color)
0
<0-1>
M14
859-0 Develop-
ment
Toner empty
detection
YALL
(color)
0
<0-1>
M Becomes “1” when
detecting the toner
empty.
0: Normal
1: Empty detected
14
859-1 M ALL
(color)
0
<0-1>
M14
859-2 C ALL
(color)
0
<0-1>
M14
860-0 Develop-
ment
Color auto-
toner sensor/
proper range
setting of OFF
level voltage
Upper limit ALL
(color)
20
<0-1023>
M Sets the range for judg-
ing whether the sensor
output value when the
sensor light source is
OFF is correct
or not.
4
860-1 Lower limit ALL
(color)
0
<0-1023>
M4
861-0 Develop-
ment
Color auto-
toner sensor/
proper range
setting of
standard light
amount volt-
age
Upper limit ALL
(color)
205
<0-255>
M Sets the range for judg-
ing whether the adjust-
ment result of sensor
light amount is correct
or not.
4
861-1 Lower limit ALL
(color)
40
<0-255>
M4
862-0 Develop-
ment
Color auto-
toner sensor/
proper range
setting of ref-
erence plate
output
Upper limit ALL
(color)
950
<0-1023>
M Sets the range for judg-
ing whether the sensor
output value for the ref-
erence plate is correct
or not.
4
862-1 Lower limit ALL
(color)
205
<0-1023>
M4
863-0 Develop-
ment
Color auto-
toner sensor/
proper range
setting of
developer out-
put
Upper limit ALL
(color)
450
<0-1023>
M Sets the range for judg-
ing whether the sensor
output value for the
sleeve is correct or not.
4
863-1 Lower limit ALL
(color)
155
<0-1023>
M4
864 Develop-
ment
Color auto-toner sensor/
sensor OFF output value
display at power ON
ALL
(color)
-
<0-1023>
M Displays the sensor
output value when the
sensor light source is
OFF at power ON.
2
865 Develop-
ment
Color auto-toner sensor/
reference plate output
value display at power ON
ALL
(color)
-
<0-1023>
M Displays the sensor
output value with the
standard light amount
for the reference plate
at power ON.
2
866-0 Develop-
ment
Color auto-
toner sensor/
abnormal
detection
potential dif-
ference set-
ting of
reference
plate output
Upper limit ALL
(color)
820
<0-1023>
M Sets the range for judg-
ing whether the differ-
ence between the
sensor output when the
sensor light source is
OFF and the sensor
output for the reference
plate is correct or not.
4
866-1 Develop-
ment
Lower limit ALL
(color)
205
<0-1023>
M4
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM Contents
Pro-
cedur
e