e-STUDIO281c/351c/451c ERROR CODE AND SELF-DIAGNOSTIC MODE June 2005 © TOSHIBA TEC
2 - 134
702 Mainte-
nance
Remote-controlled service
function
ALL 2
<0-2>
SYS 0: Valid (Remote-con-
trolled server)
1: Valid (L2)
2: Invalid
1
703 Mainte-
nance
Remote-controlled service
HTTP server
URL setting
ALL - SYS Maximum 256 Bytes 11
704-0 Interruption of
stapling oper-
ation (no sta-
ple)
Copying ALL 1
<0-1>
SYS 0: Continues printing
by switching sort
setting
1: Interrupts printing
11
704-1 Printing /
BOX print-
ing
ALL 1
<0-1>
SYS 0: Continues printing
by switching sort
setting
1: Interrupts printing
4
707 Mainte-
nance
Remote-controlled service
HTTP initially-registered
server
URL setting
ALL https://
device.mf
p-sup-
port.com:
443/
device/fir-
streg-
ist.ashx
SYS Maximum 256 Bytes 11
710 Mainte-
nance
(Remote)
Short time interval setting
of recovery from Emer-
gency Mode
ALL 24
<1-48>
SYS Sets the time interval to
recover from the Emer-
gency Mode to the Nor-
mal Mode.
(Unit: Hour)
1
711 Mainte-
nance
Short time interval setting
of Emergency Mode
ALL 60
<30-360>
SYS Unit: Minute 1
715 Mainte-
nance
Remote-controlled service
periodical polling timing
(Hour/Hour/Minute/Minute)
ALL 1230 SYS 0 (0:00) to 2359 (23:59) 1
716 Mainte-
nance
Remote-controlled service
Writing data of self-diag-
nostic code
ALL 0
<0-1>
SYS 0: Prohibited
1: Accepted
1
717 Mainte-
nance
Remote-controlled service
response waiting time
(Timeout)
ALL 3
<1-30>
SYS Unit: Minute 1
718 Mainte-
nance
Remote-controlled service
initial registration
ALL 0
<0-2>
SYS 0: OFF
1: Start
2: Only certification is
scanned
1
719 Mainte-
nance
Remote-controlled service
tentative password
ALL - SYS Maximum 10 letters 11
720 Mainte-
nance
Status of remote-con-
trolled service initial regis-
tration (Display only)
ALL 0
<0-1>
SYS 0: Not registered
1: Registered
2
721 Mainte-
nance
Service center call function ALL 2
<0-2>
SYS 0: OFF
1: Notifies all service
calls
2: Notifies all but
paper jams
1
723 Mainte-
nance
Service center call HTTP
server URL setting
ALL - SYS Maximum 256 letters 11
726 Mainte-
nance
HTTP proxy setting ALL 1
<0-1>
SYS 0: Valid
1: Invalid
1
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM Contents
Pro-
cedur
e