e-STUDIO281c/351c/451c TROUBLESHOOTING June 2005 © TOSHIBA TEC
5 - 130
(12) Perform 1*-102 (Clearing the image data).
Notes:
Following image data are deleted when 1*-102 is performed.
Images of fax polling transmission
Images of fax Mailbox and box information
Images of fax transmission
Images of fax reception
(13) Turn the power OFF.
(14) Turn the power ON.
(15) Set the dial type. [USER FUNCTIONS] [ADMIN] [FAX] [INITIAL SETUP]
5.3.3 Replacing SLG board
<CAUTION IN REPLACING SLG BOARD>
When the SLG board has been replaced, “Data transfer of characteristic value of scanner / SYS board
SLG board (05-363)” must be performed.
5.3.4 Replacing or clearing NVRAM
<<Caution in replacing or clearing NVRAM>>
When NVRAM has been replaced or cleared (”System all clearing (08-669)”), the setting must be per-
formed according to the following procedure.
<After replacing or clearing NVRAM>
(1) Take off the FAX board if installed.
(2) Start up with the Setting Mode (08).
(3) Check the serial number after performing 08-995 (Equipment number display). If the number is
different from the one on the label attached to the rear cover of the equipment, enter the correct
serial number again with 08-995.
Note: Note:
The MAC address of the equipment is generated based on this serial number. Entering the incor-
rect serial number may result in an inability to access the network due to an invalid MAC
address.
(4) Perform 08-693 (initialization of the NIC information).
(5) Perform “Data transfer of characteristic value of scanner / SLG board Æ SYS board (05-364)”.
(6) Perform “Image quality control initialization (05-396)” (Chapter 3.3), and then perform “Automatic
gamma adjustment (05-1642, 1000 and 1002)” consecutively (Chapters 3.5.1 and 3.6.1).
(7) Perform “1: Electrical counter -> Backup counter” of 08-257 (Counter copy) to recover the total
counter.
(8) Shut down the equipment.