e-STUDIO281c/351c/451c DATA CLONING with USB STORAGE DEVICE June 2005 © TOSHIBA TEC
9 - 14
(The following screens are given as an example of when all items are restored.)
(7) Press the [Start] button.
The restore starts and the restoring status is displayed on the LCD screen.
Fig. 9-19
(8) "Restore Completed" is displayed on the LCD screen when the restore has been properly com-
pleted.
Fig. 9-20
(9) Turn the power OFF and remove the USB storage device.
(10) Clear the counter (in case of restoring "Department Code" and "User Info").
Since the counter values are also copied, clear all of them. However, the total counter is not cop-
ied.
<Procedure>
Press the buttons as follows: [USER FUNCTION] →
[ADMIN] → Enter the password →
[COUNTER] → [DEPARTMENT SETTING] → Enter the password → [RESET ALL COUNTERS]
* Enable the department management when the [RESET ALL COUNTERS] button is set to be
disabled.
05/11