Toshiba e-STUDIO351c Copier User Manual


 
e-STUDIO281c/351c/451c PREVENTIVE MAINTENANCE (PM) June 2005 © TOSHIBA TEC
4 - 2
* The screen goes back to the main screen when the counter clear is performed or the [CANCEL]
button is pressed after moving from the main screen, while it goes back to the sub screen after
moving from the sub screen.
[ 2 ] Operational screen
1) Main screen
Fig.4-2
Displaying of the main unit name
Back to the PM support mode activation screen
Moving to the clear screen to clear the selected unit counters and , including all sub unit
(parts) counters belonging to that unit When the unit is not selected, all counters are cleared.
Moving to the sub screen of the selected unit
Moving to the next/previous page
Displaying of the standard number of output pages / develop counts (x1,000) to replace the
unit parts
Displaying of the present drive counts (x1,000)
“*” is displayed next to the present number when the number of drive counts has exceeded its
PM standard number.
Displaying of the standard number of drive counts (x1,000) to replace the unit parts
Displaying of the present number of output pages/develop counts (x1,000)
When there are differences among the sub units (parts), “_” is displayed and “CHECK SUB-
UNIT” is displayed at the top
“*” is displayed next to the present number when the number of output pages or develop
counts has exceeded its PM standard number.
Displaying of the number of output pages / develop counts (Page/D. cnt), drive counts (Cnt.)
and previous replacement date (Chg.) for a chosen unit
When the replacement date for the sub unit is different, press the [SUB UNIT] button to move
to the sub screen and see each information, otherwise information is not displayed
1
23 4 5 6
910
78
1
2
3 9 7
4
5
6
7
8
9
10