Toshiba e-STUDIO351c Copier User Manual


 
e-STUDIO281c/351c/451c ERROR CODE AND SELF-DIAGNOSTIC MODE June 2005 © TOSHIBA TEC
2 - 42
229-0 Transfer 2nd transfer
roller bias out-
put adjust-
ment
(Thick paper
1)
Single
side
ALL
(black)
144
<0-187>
M When the value
decreases, the 2nd
transfer roller bias out-
put increases.
The adjustment value
becomes effective
when the Setting Mode
(08-544, 549 and 551)
is 0 (invalid).
14
229-1 Reverse
side at
duplexing
ALL
(black)
119
<0-187>
M14
229-2 Single
side
ALL
(color)
125
<0-187>
M14
229-3 Reverse
side at
duplexing
ALL
(color)
112
<0-187>
M14
230-0 Transfer 2nd transfer roller bias out-
put (Thick paper 2)
ALL
(black)
153
<0-187>
M When the value
decreases, the 2nd
transfer roller bias out-
put increases.
The adjustment value
becomes effective
when the Setting Mode
(08- 544, 549 and 551)
is 0 (invalid).
14
230-1 ALL
(color)
150
<0-187>
M14
231-0 Transfer 2nd transfer roller bias out-
put (Thick paper 3)
ALL
(black)
131
<0-187>
M When the value
decreases, the 2nd
transfer roller bias out-
put increases.
The adjustment value
becomes effective
when the Setting Mode
(08- 544, 549 and 551)
is 0 (invalid).
14
231-1 ALL
(color)
131
<0-187>
M14
232-0 Transfer 2nd transfer roller bias out-
put (OHP film)
ALL
(black)
119
<0-187>
M When the value
decreases, the 2nd
transfer roller bias out-
put increases.
The adjustment value
becomes effective
when the Setting Mode
(08- 544, 549 and 551)
is 0 (invalid).
14
232-1 ALL
(color)
119
<0-187>
M14
234-0 Transfer 2nd transfer
roller bias off-
setting adjust-
ment
(Plain paper)
Single
side
ALL
(black)
5
<0-10>
M Sets the offset amount
of 2nd transfer roller
bias.
0: -500V 1: -400V
2: -300V 3: -200V
4: -100V 5: 0V
6: +100V 7: +200V
8: +300V 9: +400V
10: +500V
4
234-1 Reverse
side at
duplexing
ALL
(black)
5
<0-10>
M4
234-2 Single
side
ALL
(color)
5
<0-10>
M4
234-3 Reverse
side at
duplexing
ALL
(color)
5
<0-10>
M4
236-0 Transfer 2nd transfer
roller bias off-
setting adjust-
ment (Thick
paper 1)
Single
side
ALL
(black)
5
<0-10>
M Sets the offset amount
of 2nd transfer roller
bias.
0: -500V 1: -400V
2: -300V 3: -200V
4: -100V 5: 0V
6: +100V 7: +200V
8: +300V 9: +400V
10: +500V
4
236-1 Reverse
side at
duplexing
ALL
(black)
5
<0-10>
M4
236-2 Single
side
ALL
(color)
5
<0-10>
M4
236-3 Reverse
side at
duplexing
ALL
(color)
5
<0-10>
M4
Adjustment mode (05)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM Contents
Pro-
cedur
e