441
4. Press [Enter] to accept the default parameters, but change the following
parameter to enable boot from the network.
5. The following prompt appears for you to review the changes before saving
to flash memory.
6. At the following prompt save the configuration changes to flash
memory.
Firmware boot from ((F)lash or (N)etwork) [F] : N
New configuration to be saved as
MAC address assigned to Ethernet [00:60:2e:01:61:0c]
IP address assigned to Ethernet interface
[192.168.51.243]
Watchdog timer ((A)ctive or (I)nactive) [A]
Firmware boot from ((F)lash or (N)etwork) [N]
Boot type ((B)ootp,(T)ftp or Bot(H)) [T]
Boot File Name [zvmppckvm.bin]
Server's IP address [192.168.160.1]
Console speed [9600]
(P)erform or (S)kip Flash test [S]
(S)kip, (Q)uick or (F)ull RAM test [S]
Fast Ethernet ((A)uto Neg, (1)00 BtH, 100 Bt(F), 10
B(t)F, 10 Bt(H)) [A]
Fast Ethernet Maximum Interrupt Events [0]
Maximum rate of incoming bytes per second [0]:
Do you confirm these changes in flash ( (Y)es, (N)o
(Q)uit ) [N] : Y