Alcatel-Lucent 6600 Switch User Manual


 
Quick Steps for Configuring Switch Logging Using Switch Logging
page 28-4 OmniSwitch 6600 Family Network Configuration Guide April 2006
Quick Steps for Configuring Switch Logging
1 Enable switch logging by using the following command:
-> swlog
2 Specify the ID of the application to be logged along with the logging severity level.
-> swlog appid bridge level warning
Here, the application ID specifies bridging and the severity is set to the “warning” level.
3 Specify the output device to which the switch logging information will be sent.
-> swlog output console
In this example, the switch logging information will be sent to the console port.
Note. Optional. To verify the switch logging configuration, enter the show swlog command. The display
is similar to the one shown below:
Switch Logging is:
- INITIALIZED
- RUNNING
Log Device(s)
----------------
flash
console
Only Applications not at the level ‘info’ (6) are shown
Application ID Level
----------------------------
BRIDGE(10) warning (5)
For more information about this command, or the “Switch Logging Commands” chapter in the
OmniSwitch CLI Reference Guide.