Appendix B Specifications
200 P332G-ML User’s Guide
Safety – AC
• UL for US approved according to UL195O Std.
• C-UL(UL for Canada) approved according to C22.2 No.950 Std.
• CE for Europe approved according to EN 60950 Std.
• Laser components are Laser Class I approved:
— EN-60825/IEC-825 for Europe
— FDA CFR 1040 for USA
• Overcurrent Protection: A readily accessible Listed safety-approved protective
device with a 16A rating must be incorporated in series with building
installation AC power wiring for the equipment under protection.
EMC Emissions
Emissions
Approved according to:
• US - FCC Part 15 sub part B, class A
• Europe - EN55022 class A and EN61000-3-2
• Japan - VCCI-A
Immunity
Approved according to:
• EN 55024 and EN61000-3-3
Interfaces
• P332G-ML: 12 x SFP pluggable Gigabit Ethernet fiber optic connectors.
• RS-232 for terminal setup via RJ-45 connector on front panel.
Standards Compliance
The P332G-ML complies with:
IEEE
• IEEE 802.3x Flow Control
• IEEE 802.1q/p VLAN Tagging and 802.1p compatible
• IEEE 802.1D Spanning Tree protocol
• IEEE 803.3z Gigabit Ethernet ports