Chapter 5 CLI – Layer 2
P332G-ML User’s Guide 57
etc.
Note: Port security for the P332G-ML and P332GT-ML will always have the value
unknown. This command is used to display the security status for the other P330
modules in the stack.
Show internal buffering Command
This shows the size options (Maximum, Minimum, or Medium) of the Receive (Rx)
buffer allocated to each port of the specified module.
The syntax for this command is:
show internal buffering [<mod_num>]
Example:
P330-N> show internal buffering 1
Module Internal Buffer
------ ---------------
1 med
Note: This command is not supported P332G-ML and P332GT-ML modules and
should be used only for the other P330 modules in the stack .
Show boot bank Command
Use the show boot bank command to display the software bank from which the
module will boot at the next boot process. This command should be issued
separately for each module in the stack using the session command.
Note: This command is not supported by the P333R and P333R-LB switches.
The syntax for this command is:
show boot bank
Example:
Boot bank set to bank-a