CHAPTER 8 16-BIT TIMER/EVENT COUNTER
(1) Capture/compare register 00 (CR00)
CR00 is a 16-bit register which has the functions of both a capture register and a compare register. Whether
it is used as a capture register or as a compare register is set by bit 0 (CRC00) of capture/compare control
register 0.
When CR00 is used as a compare register, the value set in CR00 is constantly compared with the 16-bit timer
register (TM0) count value, and an interrupt request (INTTM00) is generated if they match. It can also be
used as the register which holds the interval time when TM0 is set to interval timer operation, and as the register
which sets the pulse width when TM0 is set to PWM operating mode.
When CR00 is used as a capture register, it is possible to select the valid edge of the INTP0/TI00 pin or the
INTP1/TI01 pin as the capture trigger. The valid edge of INTP0/TI00 and INTP1/TI01 are set by external
interrupt mode register 0 (INTM0).
If CR00 is specified as a capture register and capture trigger is specified to be the valid edge of the INTP0/
TI00 pin, the situation is as shown in the following table.
Table 8-5. INTP0/TI00 Pin Valid Edge and CR00 Capture Trigger Valid Edge
ES11 ES10 INTP0/TI00 Pin Valid Edge CR00 Capture Trigger Valid Edge
0 0 Falling edge Rising edge
0 1 Rising edge Falling edge
1 0 Setting prohibited
1 1 Both rising and falling edges No capture operation
Remark ES10, ES11: Bits 2 and 3 of external interrupt mode register 0 (INTM0)
CR00 is set by a 16-bit memory manipulation instruction.
After RESET input, the value of CR00 is undefined.
Cautions 1. Set the data of PWM (14 bits) to the higher 14 bits of CR00. At this time, clear the lower
2 bits to 00.
2. Set a value other than 0000H to CR00. When the event counter function is used, therefore,
one pulse cannot be counted.
3. If the new value of CR00 is less than the value of the 16-bit timer register (TM0), TM0
continues counting, overflows, and then starts counting again from 0. If the new value
of CR00 is less than the old value, the timer must be restarted after changing the value
of CR00.
(2) Capture/compare register 01 (CR01)
CR01 is a 16-bit register which has the functions of both a capture register and a compare register. Whether
it is used as a capture register or a compare register is set by bit 2 (CRC02) of capture/compare control register
0.
When CR01 is used as a compare register, the value set in the CR01 is constantly compared with the 16-
bit timer register (TM0) count value, and an interrupt request (INTTM01) is generated if they match.
When CR01 is used as a capture register, it is possible to select the valid edge of the INTP0/TI00 pin as the
capture trigger. The valid edge of INTP0/TI00 is set by interrupt mode register 0 (INTM0).
CR01 is set with a 16-bit memory manipulation instruction.
After RESET input, the value of CR01 is undefined.