SMSC LAN9311 Switch User Manual


 
Two Port 10/100 Managed Ethernet Switch with 16-Bit Non-PCI CPU Interface
Datasheet
SMSC LAN9311/LAN9311i 375 Revision 1.4 (08-19-08)
DATASHEET
14.5.3.6 Switch Engine ALR Command Status Register (SWE_ALR_CMD_STS)
This register indicates the current ALR command status.
Note 14.62 The default value of this bit is 0 immediately following any switch fabric reset and then self-
sets to 1 once the ALR table is initialized.
Register #: 1808h Size: 32 bits
BITS DESCRIPTION TYPE DEFAULT
31:2 RESERVED RO -
1
ALR Init Done
When set, indicates that the ALR table has finished being initialized by the
reset process. The initialization is performed upon any reset that resets the
switch fabric. The initialization takes approximately 20uS. During this time,
any received packet will be dropped. Software should monitor this bit before
writing any of the ALR tables or registers.
RO
SS
Note 14.62
0
Make Pending
When set, indicates that the Make Entry command is taking place. This bit
is cleared once the Make Entry command has finished.
RO
SC
0b