SMSC LAN9311 Switch User Manual


 
Two Port 10/100 Managed Ethernet Switch with 16-Bit Non-PCI CPU Interface
Datasheet
SMSC LAN9311/LAN9311i 449 Revision 1.4 (08-19-08)
DATASHEET
15.5.5 PIO Burst Read Cycle Timing
Please refer to Section 8.5.5, "PIO Burst Reads," on page 108 for a functional description of this mode.
Note: A host PIO burst read cycle begins when both nCS and nRD are asserted. The cycle ends
when either or both nCS and nRD are de-asserted. These signals may be asserted and de-
asserted in any order.
Note: A[1] must toggle, fresh data is supplied each time A[1] toggles.
Figure 15.5 PIO Burst Read Cycle Timing
Table 15.9 PIO Burst Read Cycle Timing Values
SYMBOL DESCRIPTION MIN TYP MAX UNITS
t
csh
nCS, nRD De-assertion Time 13 nS
t
csdv
nCS, nRD Valid to Data Valid 30 nS
t
acyc
Address Cycle Time 45 nS
t
asu
Address Setup to nCS, nRD Valid 0 nS
t
adv
Address Stable to Data Valid 40 nS
t
ah
Address Hold Time 0 nS
t
don
Data Buffer Turn On Time 0 nS
t
doff
Data Buffer Turn Off Time 9 nS
t
doh
Data Output Hold Time 0 nS
A[4:1]
nCS, nRD
D[15:0]
A[x:5], END_SEL
t
asu
t
acyc
t
acyc
t
acyc
t
ah
t
csh
t
adv
t
adv
t
adv
t
csdv
t
don
t
doh
t
doff