Compaq EV67 Network Card User Manual


 
Alpha 21264/EV67 Hardware Reference Manual
Thermal Management 10–1
10
Thermal Management
This chapter describes the 21264/EV67 thermal management and thermal design
considerations, and is organized as follows:
Operating temperature
Heat sink specifications
Thermal design considerations
10.1 Operating Temperature
The 21264/EV67 is specified to operate when the temperature at the center of the heat
sink (T
c)
is as shown in Table 10–1. Temperature T
c
should be measured at the center of
the heat sink, between the two package studs. The GRAFOIL pad is the interface mate-
rial between the package and the heat sink.
Note: Compaq recommends using the heat sink because it greatly improves the
ambient temperature requirement.
Table 10–1 Operating Temperature at Heat Sink Center (T
c
)
T
c
Frequency
80.2° C 600 MHz
78.1° C 667 MHz
76.9° C 700 MHz
76.0° C 733 MHz
75.4° C 750 MHz
72.7° C 833 MHz