AMD LX 900@1.5W Computer Hardware User Manual


 
AMD Geode™ LX Processors Data Book 219
GeodeLink™ Memory Controller Register Descriptions
33234H
6.2 GeodeLink™ Memory Controller Register Descriptions
All GLMC registers are Model Specific Registers (MSRs)
and are accessed via the RDMSR and WRMSR instruc-
tions.
The registers associated with the GLMC are the Standard
GeodeLink Device (GLD) MSRs and GLMC Specific
MSRs. Table 6-5 and Table 6-6 are register summary
tables that include reset values and page references where
the bit descriptions are provided.
Note: MSR addresses are documented using the CPU
Core as the source. Refer to Section 4.1 "MSR
Set" on page 45 for further details.
Table 6-5. Standard GeodeLink™ Device MSRs Summary
MSR
Address Type Register Name Reset Value Reference
20002000h RO GLD Capabilities MSR (GLD_MSR_CAP) 00000000_000204xxh Page 220
20002001h --- GLD Master Configuration MSR
(GLD_MSR_CONFIG) - Not Used
00000000_00000000h Page 220
20002002h R/W GLD SMI MSR (GLD_MSR_SMI) 00000000_00000000h Page 220
20002003h R/W GLD Error MSR (GLD_MSR_ERROR) 00000000_00000000h Page 221
20002004h R/W GLD Power Management (GLD_MSR_PM) 00000000_00000000h Page 222
20002005h R/W GLD Diagnostic (GLD_MSR_DIAG) 00000000_00000000h Page 222
Table 6-6. GLMC Specific MSR Summary
MSR
Address Type Register Name Reset Value Reference
20000010h RO Row Addresses Bank0 DIMM0, Bank1 DIMM0
(MC_CF_BANK01)
xxxxxxxx_xxxxxxxxh Page 223
20000011h RO Row Addresses Bank2 DIMM0, Bank3 DIMM0
(MC_CF_BANK23)
xxxxxxxx_xxxxxxxxh Page 223
20000012h RO Row Addresses Bank4 DIMM0, Bank5 DIMM0
(MC_CF_BANK45)
xxxxxxxx_xxxxxxxxh Page 224
20000013h RO Row Addresses Bank6 DIMM0, Bank7 DIMM0
(MC_CF_BANK67)
xxxxxxxx_xxxxxxxxh Page 224
20000014h RO Row Addresses Bank0 DIMM1, Bank1 DIMM0
(MC_CF_BANK89)
xxxxxxxx_xxxxxxxxh Page 225
20000015h RO Row Addresses Bank2 DIMM1, Bank3 DIMM1
(MC_CF_BANKAB)
xxxxxxxx_xxxxxxxxh Page 225
20000016h RO Row Addresses Bank4 DIMM1, Bank5 DIMM1
(MC_CF_BANKCD)
xxxxxxxx_xxxxxxxxh Page 226
20000017 RO Row Addresses Bank6 DIMM1, Bank7 DIMM1
(MC_CF_BANKEF)
xxxxxxxx_xxxxxxxxh Page 226
20000018h R/W Refresh and SDRAM Program
(MC_CF07_DATA)
10071007_00000040h Page 227
20000019h R/W Timing and Mode Program (MC_CF8F_DATA) 18000008_287337A3h Page 229
2000001Ah R/W Feature Enables (MC_CF1017_DATA) 00000000_11080001h Page 231
2000001Bh RO Performance Counters (MC_CFPERF_CNT1) 00000000_00000000h Page 232
2000001Ch R/W Counter and CAS Control (MC_PERCNT2) 00000000_00FF00FFh Page 233
2000001Dh R/W Clocking and Debug (MC_CFCLK_DBUG) 00000000_00001300h Page 233
2000001Eh RO Page Open Status (MC_CFPG_OPEN) 00000000_0000FFFFh Page 235