980 Brocade Network Advisor IP User Manual
53-1003056-01
SAN real-time performance data
33
RX FCIP SNMP .1.3.6.1.2.1.31.1.1.1.6 RX = (delta value
1
/ (1000 * 1000)) /
(polling interval
2
)
Uncompressed
Tx/Rx MB/sec
FCIP SNMP .1.3.6.1.4.1.1588.4.1.1.6 (delta value
1
/ (1000 * 1000)) /
(polling interval
2
)
TX EE Monitors HTTP PortRX (variable from the
return html file)
TX = (delta value
1
/ (1000 * 1000)) /
(polling interval
2
)
RX EE Monitors HTTP PortTX (variable from the
return html file)
RX = (delta value
1
/ (1000 * 1000)) /
(polling interval
2
)
TX HBA, CNA HCM API N/A TX = (delta value
1
/ (1000 * 1000)) /
(polling interval
2
)
RX HBA, CNA HCM API N/A RX = (delta value
1
/ (1000 * 1000)) /
(polling interval
2
)
TX TE SNMP .1.3.6.1.2.1.31.1.1.1.6 TX = (delta value
1
/ (1000 * 1000)) /
(polling interval
2
)
RX TE SNMP .1.3.6.1.2.1.31.1.1.1.10 RX = (delta value
1
/ (1000 * 1000)) /
(polling interval
2
)
TX% / RX% FC, GE,
HBA, CNA
N/A N/A TX% or RX% = ((TX or RX) /
((105000000 * port speed)*
(polling interval
2
))) * 100
If utilization is less than 1, the value is 0.0.
TX% / RX% FCIP N/A N/A TX% or RX% = ((bytes transferred) / (maximum bytes
transmitted))*100 where maximum bytes transmitted = tunnel
speed * 134217728 (maximum bytes transmitted 1 Gbps).
If utilization is less than 1, the value is 0.0.
TX% / RX%
(Pre-Fabric OS
6.4.1 release)
TE N/A N/A TX% or RX% = ((TX or RX) /
((105000000 * 10)*
(polling interval
2
))) * 100
If utilization is less than 1, the value is 0.0.
Cumulative
Compression
Ratio
FCIP N/A .1.3.6.1.4.1.1588.4.1.1.4 Compression Ratio = current value/ 1000
The compression ratio is the current compression ratio value.
Current
Compression
Ratio
FCIP N/A N/A (ifHCInOctets + ifHCOutOctets) /
fcipExtendedLinkCompressedBytes
Receive EOF TE .1.3.6.1.2.1.16.1.1.1.5 Receive EOF = delta value
1
/
(1000 * 1000)
Other
3
Other counters = delta value
1
1. The difference of the value retrieved between two consecutive polling cycles.
2. The duration between two polling cycle in seconds.
3. Additional performance counters are detailed in Table 86.
TABLE 86 Performance statistic counters
Counter name Type Protocol Source OID value Formula