Brocade Network Advisor IP User Manual 85
53-1003056-01
Individual IP device discovery
3
NOTE
You can configure both SNMPv3 and SNMPv1/SNMPv2c credentials at the same time;
however, discovery tries the SNMPv3 credentials before trying the SNMPv1 and SNMPv2c
credentials.
5. Configure the SNMPv3 read-write credentials by completing the following steps.
NOTE
These credentials are not applicable for DCB devices.
a. Click the SNMPv3 Read/Write tab.
FIGURE 36 SNMPv3 credentials
b. Enter the SNMPv3 user name in the User ID field.
The user name can be from 1 through 16 characters long, case sensitive, and allows all
printable ASCII characters.
c. Select one of the following protocols from the Authentication Protocol list:
None
HMAC_MD5
HMAC_SHA
d. Enter the SNMPv3 authentication password in the Authentication Password field.
The password can be from 8 through 16 characters long, case sensitive, and allows all
printable ASCII characters. The password display as asterisks.
e. Select one of the following protocols from the Privacy Protocol list:
None
CBC-DES
CFB_AES-128
If you select a privacy protocol, the selected protocol encrypts the SNMP request and
response packets.
f. Enter the privacy password in the Privacy Password field.
The password can be from 1 through 16 characters long, case sensitive, and allows all
printable ASCII characters. The password display as asterisks.
6. Configure the SNMPv3 read only credentials by completing the following steps.