NETGEAR XS712T-100NES Switch User Manual


 
102
XS712T Smart Switch
3. Click Apply.
4. V
iew the MSTP status information displayed on the Spanning Tree CST Configuration
screen.
Field Description
MST ID Table consisting of the MST instances (including the CST) and the
correspo
nding VLAN IDs associated with each of them.
VID Table consisting of the VLAN IDs and the corresponding FID
associated with each of them
FID Table consisting of the FIDs and the corresponding VLAN IDs
associa
ted with each of them.
5. Click Refresh to update the information on the screen with the most current data.
CST Port Configuration
Use the CST Port Configuration screen to configure Common Spanning Tree (CST) and
Internal Spanning Tree on a specific port on the switch.
To configure CST port settings:
1. Select Sw
itching STP Advanced CST Port Configuration.
2. To configure CST settings for a physical port, enter the interface and click Go to select that
particular interface.
3. Select
the interfaces for which you want to configure the CST settings:
T
o configure CST settings for a Link Aggregation Group (LAG), click LAGS.
T
o configure CST settings for both physical ports and LAGs, click ALL.