246
XS712T Smart Switch
Use the buttons at the bottom of the screen to perform the following actions:
• To clear all the EAP counters for all ports on the switch, select the check box in the
row heading and click Clear. The button resets all statistics for all ports to default
values.
• To clear the counters for a specific port, select the check box associated with the port
and click Clear.
• Click Refresh to refresh the data on the screen and display the most current statistics.
Invalid Frames Received The number of unrecognized EAPOL frames received on this port.
Length Error Frames Received The number of EAPOL frames with an invalid Packet Body Length
received on this port.
Response/ID Frames Received The number of EAP Respond ID frames that have been received on
the port.
Response Frames Received The number of valid EAP Response frames received on the port.
Request/ID Frames
Transmitted
The number of EAP Requested ID frames transmitted through the
port.
Request Frames Transmitted The number of EAP Request frames transmitted through the port.
Table 40. EAP statistics (Continued)
Field Description