Use the LLDP Configuration screen to specify the global LLDP and LLDP-MED parameters
that are applied to the switch.
To configure global LLDP settings:
1. Select System > LL
DP > Basic > LLDP Configuration.
The LLDP Configuration screen displays.
2. Optionally, configure non-default values for the following LLDP properties.
• TL
V Advertised Interval: The number of seconds between transmissions of LLDP
advertisements.
• Hold Mu
ltiplier: The Transmit Interval multiplier value, where Transmit Hold Multiplier
× Transmit Interval = the time to live (TTL) value the device advertises to neighbors.
• Reinitial
izing Delay: The number of seconds to wait before attempting to reinitialize
LLDP on a port after the LLDP operating mode on the port changes.
• T
ransmit Delay: The minimum number of seconds to wait between transmissions of
remote data change notifications to the SNMP trap receiver(s) configured on the
device.
3. Option
ally, configure a non-default value next to Fast Start Duration.
This value sets the number of LLDP packets sent when the LLDP-MED Fast Start
mechanism is initialize
d, which occurs when a new endpoint device links with the
LLDP-MED network connectivity device.
4. Click Apply.