260
XS712T Smart Switch
Factory Default
Use the Factory Default screen to reset the system configuration to the factory default values.
Note: If you reset the switch to the default configuration, the IP address is
reset to 192.168.0.239, and the DHCP client is enabled. If you loose
network connectivity after you reset the switch to the factory
defaults, see Connect the Switch to the Network on page 8.
To reset the switch to the factory default settings:
1. Select Main
tenance Reset Factory Default.
2. Select the check box on the screen.
3. Click Apply. The switch
resets immediately.
Upload
The switch supports system file uploads from the switch to a remote system by using either
TFTP or HTTP.
The Upload menu contains links described in the
following sections.
• TFTP File Upload
• HTTP File Upload