Avaya P580 Switch User Manual


 
5-30 Avaya P550R, P580, P880, and P882 Multiservice Switch User Guide, v5.3.1
Chapter 5
Example Refer to Table 5-6 as an example of the recommended switch port
settings for a Cisco Catalyst 5000
TM
.
CLI Command To configure switch ports using the CLI, enter the following
command from Configure mode:
<configure># set port <options>
Refer to the Command Reference Guide for the Avaya P550R, P580, P880,
and P882 Multiservice Switches, Version 5.3for more details about this
command.
* Note: See the examples later in this section for
recommendations on how to set particular trunk port
connections.
Refer to “VLAN Operation” in Chapter 4 for more
information on creating VLANs.
You can configure port VLAN parameters using either
the Web Agent or the CLI.
Automatic VLAN Creation
Automatic VLAN creation is done by enabling the ‘Automatic VLAN
Creation’ parameter on an individual port under the ‘Module &
Ports’>Configuration >Switch Ports > name menu. With this
parameter enabled, the port will automatically create a VLAN each
time it receives a frame from an unknown VLAN ID in received
IEEE 802.1Q and Multi-Layer tagged frames.
Table 5-6. Example 1. Trunk to Cisco Catalyst 5000
TM
Parameter Recommended Setting
Port VLAN Default - Causes untagged packets to be assigned to
the default VLAN.
Trunk Mode Multi-layer - Causes the port to send frames using
the multi-layer format.
VLAN Binding Bind to All - Binds the port to all VLANs known to
the switch.
Automatic
VLAN Creation
Enable (Disable if using VTP Snooping) - Causes
the switch to learn new VLAN IDs that arrive at the
port, and then bind the port to these VLANs.
VTP Snooping Enable - Causes the switch to update its VLANs as
they are created, deleted, or changed on the Catalyst.