Avaya P580 Switch User Manual


 
17-4 Avaya P550R, P580, P880, and P882 Multiservice Switch User Guide, v5.3.1
Chapter
2. Refer to Table 6-110 to set the threshold values:
Using the CLI To check the temperature status using the CLI, enter the following
command from Configuration mode:
<configure># show temperature
To Configure temperature threshold values using the CLI, enter the
following command from Configuration) mode:
<configure># set temperature <options (backplane
sensor, CPU-sensor, probe, supervisor-slot)>
Refer to the Command Reference Guide for the Avaya P550R, P580, P880,
and P882 Multiservice Switches, v5.3.1 for details about these
commands.
Table 6-110. Temperature Threshold Values
Threshold Defines...
Shutdown
Temperature
Value in degrees Celsius that causes the switch to send a
trap to the network management station and triggers a
shutdown when it is passed. The default value is 100
degrees Celsius.
Upper Warning
Temperature
Value in degrees Celsius that causes the switch to send a
high temperature threshold warning when it is passed. The
default value is 85 degrees Celsius.
Lower Warning
Temperature
Value that in degrees Celsius that when passed causes the
switch to send a warning that the temperature is
approaching the low temperature threshold. By default,
this value is 5 degrees Celsius.
Low Shutdown
Temperature
Indicates the low shutdown temperature for a switch to
reset the warning and high thresholds. This value prevents
the switch from sending traps continually if the
temperature is hovering around the threshold value. The
default value is 0 degrees Celsius.