Black Box LGB5128A Network Hardware User Manual


 
LGB5128A User Manual
152
Parameter description:
Receiver Id :
The “Receiver ID” input fields allow the user to select the receiver ID. It indicates the ID of
this particular sFlow Receiver. Currently, one ID is supported and one collector is
supported.
IP Type :
A drop-down list to select the type of IP of Collector is displayed. By default, IPv4 is the
type of Collector IP type. You could use IPv4 or IPv6.
IP Address :
Enter the address of a reachable IP into the text box.
This IP is used to monitor the sFlow samples sent by sFlow Agent(our switch).
By default, The IP is set to 0.0.0.0,and a new entry has to be added to it.
Port :
A port to listen to the sFlow Agent has to be configured for the Collector.
Typ the value of the port number into the text box.
The value accepted is within the range of 165535. Configure an appropriate port number
not used by other protocols. By default, the port's number is 6343.
Time out :
This is the duration during which the collector receives samples, Once it expires, the
sampler stops sending the samples. Through the management, the value is set before it
expires. The value accepted is within the range of 02147483647. By default it is set to 0.
Datagram Size :
This is the maximum UDP datagram size to send out the sFlow samples to the receiver.
The value accepted is within the range of 2001500 bytes. The default is 1400 bytes.
Buttons:
SaveClick to save changes.
Reset- Click to undo any changes made locally and revert to previously saved
values.