Black Box LGB5128A Network Hardware User Manual


 
41
Figure 3-2.2: The ACL Rate Limiter Configuration
Parameter description:
Rate Limiter ID :
The rate limiter ID for the settings contained in the same row.
Rate
The allowed values are: 0-3276700 in pps or 0, 100, 200, 300, ..., 1000000 in
kbps.
Unit :
Specify the rate unit. The allowed values are:
pps: packets per second.
kbps: Kbits per second.
Buttons
SaveClick to save changes.
Reset- Click to undo any changes made locally and revert to previously saved
values.
3-2.3 Access Control List
The section describes how to configure Access Control List rule. An Access Control List (ACL)
is a sequential list of permit or deny conditions that apply to IP addresses, MAC addresses, or
other more specific criteria. This switch tests ingress packets against the conditions in an ACL
one by one. A packet will be accepted as soon as it matches a permit rule, or dropped as
soon as it matches a deny rule. If no rules match, the frame is accepted. Other actions can
also be invoked when a matching packet is found, including rate limiting, copying matching
packets to another port or to the system log, or shutting down a port.
This page shows the Access Control List (ACL), which is made up of the ACEs defined on
this switch. Each row describes the ACE that is defined. The maximum number of ACEs is
256 on each switch. Click on the lowest plus sign to add a new ACE to the list. The reserved
ACEs used for internal protocol, cannot be edited or deleted, the order sequence cannot be
changed an the priority is highest.