13
Troubleshooting and Diagnostics
13-19
UltraNet Edge 3000 Diagnostic Programs
UltraNet Edge 3000 Diagnostic Programs
This section provides information for each of the diagnostic programs
currently available for the UltraNet Edge 3000.
NOTE: Some tests may take several minutes to complete, while others will
take very little time. At any time you can issue a control-c (^C) key to
interrupt and stop a diagnostic test.
CHARM Diagnostic
Program (ACHT)
The UltraNet Edge 3000 CHARM ATM/POS diagnostic program
resides on the UltraNet Edge 3000’s flash drive as the file acht.dll.
Using the PROM interface, the file must be loaded into memory and
executed from there.
This program tests the UltraNet Edge 3000’s CHARM ATM/POS
WAN interface and verifies that it can perform memory transfer
functions across the primary PCI bus and local memory. Test data can
be looped back either internally or externally.
Individual tests can be selected from the menu or the “Execute All”
option can be used to run tests 3 thru 10, and 17.
On Bus # 2 Device # 1
Device/Vendor ID read from board 0 PCI ConfigWord0 =
1029103C
On Bus # 3 Device # 1
Device/Vendor ID read from board 0 PCI ConfigWord0 =
00A11014
Sub Sys ID / Vendor ID read from offset 0x002C Reg =
015E1014
+++ IBM CHARM Rev 2.7 Device Found On Bus #3, Device #1!
Quick EPROM Check was Successful.
Doing Quick Charm Memory Test. Quick Memory Test Passed.
PHY Type Detected is PM5384 OC-3 type.
**** 1 ATM Board Found, OC-3 Count = 1 ****
Clearing Buffer Memory - 128MB
*> SBTM ATM CHARM Diagnostic Test Revision 1.1 – February
11, 2002 <*
MAIN MENU