H-1
H
Manual Configuration of
the Initial IP Settings
This procedure should only be used to initially configure the IP
settings. This is only necessary when the PC which has UltraNet
ConfigManager installed on it, is not able to be on the same subnet as
the UltraNet Edge 3000. Manual configuration uses the Command
Line Interface to configure the initial IP settings for the Maintenance
IP Port. This allows UltraNet ConfigManager to communicate and
deliver a configuration to the UltraNet Edge 3000 after the initial
settings have been done.
Manually Configure the Maintenance IP Port using the
Command Line Interface
Before you begin: You need the Maintenance Port IP address, default
gateway address, and subnet mask to complete this procedure. If you
have completed a Configuration Worksheet,
the addresses needed to
configure these parameters are shown in Fields A, B, F, and G.
Use the following procedure to manually configure the Maintenance
IP Port:
8. Connect the McDATA supplied RS-232 serial cable to the port
labeled, Serial on the front of the UltraNet Edge 3000. Connect
the other end of the RS-232 cable into the McDATA supplied
adapter, labeled EE.
9. Connect the EE connector to the 9 pin serial interface of the PC
which has UltraNet ConfigManager installed on it.