3
3-30
McDATA® Sphereon 3032 and 3232 Fabric Switches Installation and Service Manual
Diagnostics
b. Ensure the AC power cord is not damaged. If damaged, replace
the cord.
Was a corrective action performed?
YES NO
Go to step 8.
7
Verify power supply operation.
a. Inspect the power supply and ensure the green LED illuminates.
b. At the Hardware View, observe the graphic representing the
power supply and ensure a failure symbol (blinking red and
yellow diamond) does not appear.
Is a failure indicated?
YES NO
The switch appears operational.
8
Ensure the power supply is correctly installed and seated in the CTP
card. If required, partially remove and reseat the power supply.
Was a corrective action performed?
YES NO
Go to step 10.
9
Verify power supply operation.
a. Inspect the power supply and ensure the green LED illuminates.
b. At the Hardware View, observe the graphic representing the
power supply and ensure a failure symbol (blinking red and
yellow diamond) does not appear.
Is a failure indicated?
YES NO
The switch appears operational.
10
A redundant power supply failed and must be removed and replaced.
(RRP: Power Supply on page 5-4).