McDATA 3032 Switch User Manual


 
B
B-22
McDATA® Sphereon 3032 and 3232 Installation and Service Manual
Event Code Tables
Event Code: 203
Message: Power supply ac voltage recovery
Severity: Informational
Explanation: The ac voltage on the indicated power supply has been restored. This event can only occur when dual power
supplies are installed. Both supplies automatically adjust to share the system load.
Action: No action required.
Event Data: No supplementary data included with this event.
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔
Event Code: 204
Message: Power supply DC voltage recovery
Severity: Informational
Explanation: The DC voltage on the indicated power supply has been restored. This event can only occur when dual power
supplies are installed. Both supplies automatically adjust to share the system load.
Action: No action required.
Event Data: No supplementary data included with this event.
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔