McDATA 3032 Switch User Manual


 
B
B-12
McDATA® Sphereon 3032 and 3232 Installation and Service Manual
Event Code Tables
Event Code: 074
Message: ISL frame delivery error threshold.
Severity: Informational
Explanation: The number of fabric controller frame delivery erors exceeded a threshold over an E_Port and frabric init
problems (event 73) were detected. Most fabric init problems are due to control fram e delivery problems. This
event provides an indication of undelivered frames after they have caused problems with the fabric initialization
process.
Action: Perform a data collection operation and contact a service representative.
Event Data: Byte 0: E_Port port number.
Byte 1-3 : Reserved
Byte 4 - 7: Count of frame delivery timeout indications.
Byte 8 - 11: Count of frame delivery abort indications.
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔
Event Code: 080
Message: Unauthorized world wide name
Severity: Informational
Explanation: The world wide name of the switch connected to the indicated port is not authorized for that port.
Action: Either change the port binding definition, or connect the correct switch to this port.
Event Data: Byte 0 = failing port number.
Bytes 1 - 3 = reserved.
Bytes 4 - 11 = World wide name of the unauthorized device.
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator