McDATA 3032 Switch User Manual


 
4
4-44
McDATA® Sphereon 3032 and 3232 Fabric Switches Installation and Service Manual
Repair Information
As the network connection drops, the Status table turns
yellow, the Status field displays No Link, and the State field
displays a reason message.
The alert panel at the bottom of the navigation control panel
displays a grey square, indicating switch status is unknown.
Illustrated FRUs (SFPs, fans, and power supplies) in the
Hardware View disappear, and appear again as the connection
is re-established.
IPL the Switch
To IPL the switch:
1. At the EFC Server, open the EFC Manager application. The
Product View displays.
2. Select the icon representing the switch to be IPLed. The Hardware
View for the selected switch displays.
3. At the navigation control panel, select IPL from the Maintenance
menu. The Information dialog box displays
.
4. Click Yes to IPL the switch. During the IPL, the switch-to-EFC
Server Ethernet link drops momentarily and the following occur
at the Product Manager application:
As the network connection drops, the Status table turns
yellow, the Status field displays No Link, and the State field
displays a reason message.
The alert panel at the bottom of the navigation control panel
displays a grey square, indicating switch status is unknown.
Illustrated FRUs (SFPs, fans, and power supplies) in the
Hardware View disappear, and appear again as the connection
is re-established.