McDATA 3032 Switch User Manual


 
5
RRP: CTP Card - Switch Replacement
5-9
FRU Removal and Replacement
5. Set the IP address, subnet mask, and gateway address
the same as the failed switch and press Enter.
6. Close Hyperterminal and disconnect the maintenance
terminal.
Connect the switch to the LAN.
Configure the switch for the EFCM application:
1. Right click in a blank area of the EFCM product view and
select new.
2. Type the IP address of the switch in the new product
dialog box.
3. Select the correct product type from the product type
field and click OK. A new icon will display on the product
view.
Configure the switch identification:
1. Click on the new icon to open the hardware view and
click the configure icon.
2. Select identification from the configure menu.
3. In the configure identification dialog box, type the name,
description, location, and contact the same as the failed
switch.
Configure switch and fabric parameters:
1. Set the switch offline.
2. Select Switch Parameters from the Operating Parameters
submenu (Configure menu tab).
3. On the Configure Switch Parameters dialog box, set
Domain ID, Management Style, Rerouting Delay, and
RSCNs the same as the failed switch and click Activate.
4. Select Fabric Parameters from the Operating Parameters
submenu (Configure menu tab).
5. Set BB_Credit, R_A_TOV, E_D_TOV, Switch Priority,
and Interop Mode the same as the failed switch, and click
Activate.
Verify the firmware version: