McDATA 3032 Switch User Manual


 
B
CTP Card Events (400 through 499)
B-41
Event Code Tables
Event Code: 442
Message: Embedded Port Anomaly Detected
Severity: Informational
Explanation: Indicates that the control processor has detected a deviation in the normal operation mode or operation status of
the embedded port.
Action: No action required. There will be an additional event generated if the occurrence of this incident exceeds an error
threshold resulting in a module or port failure.
Event Data: Word 0:
Byte 0 = Embedded port number
Byte 1 = Reason Code (See following chart)
Word 1:
Byte 0 - 3 = Elapsed millisecond tick count
Word 2:
Byte 0 -1 = High availability error callout #1
Byte 2 - 3 = High availability error callout #2
Word 3:
Byte 0 = Detecting port
Byte 1 = Connected port
Byte 3 = Reserved
Word 4:
Byte 0 -1 = High availability error callout #3
Byte 2 - 3 = High availability error callout #4
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔
Event #442 Anomaly Reason Codes
Reason Code Description Additional Data
0x00 Utility bus error to SBAR HA Error Callouts (Words 2 & 4)
0x01 Utility bus error to Port Module HA Error Callouts (Words 2 & 4)
0x02 Reserved HA Error Callouts (Words 2 & 4)