McDATA 3032 Switch User Manual


 
3
MAP 0700: Fabric, ISL, and Segmented Port Problem Determination
3-103
Diagnostics
c. Inspect the Reason field for the port.
Is the Reason field blank or does it display an N/A message?
NO YES
The switch ISL appears operational.
The Reason field displays a reason message. The following table lists
segmentation reasons and associated steps that describe fault
isolation procedures.
20
A switch E_Port segmented because no switch in the fabric is capable
of becoming the principal switch.
a. Notify the customer that the switch will be set offline. Ensure the
system administrator quiesces Fibre Channel frame traffic
through the switch and sets attached devices offline.
b. Set the switch offline (Set Offline State on page 4-46)
c. At the Hardware View for the selected switch, click the Configure
menu tab and select Fabric Parameters from the Operating
Parameters sub menu. The Configure Fabric Parameters dialog
box displays.
Segmentation Reason Action
Incompatible operating parameters. Go to step 12.
Duplicate domain IDs. Go to step 13.
Incompatible zoning configurations. Go to step 14.
Build fabric protocol error. Go to step 15.
No principal switch. Go to step 20.
No response from attached switch. Go to step 17.