McDATA 3032 Switch User Manual


 
A
A-22
McDATA® Sphereon 3032 and 3232 Installation and Service Manual
Messages
Message Invalid value for second (0 - 59).
Description Value for second must be an integer from 0 through 59.
Action Enter a value from 0 through 59.
Message Invalid value for threshold (1-99)%.
Description Value entered for each port in the Configure Open Trunking dialog box
must be in the range from 1 to 99. This message only displays if the
optional Open Trunking feature is installed.
Action Enter a number from 1 to 99 into the Threshold % column of the
Configure Open Trunking dialog box.
Message Invalid value for year.
Description Value for year must be a four-digit year after 1980.
Action Enter a correct four-digit value for the year.
Message Invalid World Wide Name.
Description World wide name must have eight two-digit hexadecimal numbers
separated by colons (xx:xx:xx:xx:xx:xx:xx:xx).
Action Enter a worldwide name using eight two-digit hexadecimal numbers
separated by colons in the format given in the message.
L
Message Link dropped.
Description Connection between EFC Server and the switch has been lost.
Action Wait for the connection to re-establish. Link re-connects are
attempted every 30 seconds.
Message Log is currently in use.