B
Port Module Events (500 through 599)
B-63
Event Code Tables
Event Code: 583
Message: Loss-of -signal or loss-of-synchronization
Severity: Major
Explanation: A loss-of-synchronization condition has been recognized by the incident node and it has persisted for more than
the R_T_TOV timeout period. A loss-of-signal condition has been recognized by the incident node (see FC-PH
clause 16.4.2).
Action: A link-incident record (LIR) is generated and sent to the host using the Link-Incident reporting procedure defined
in the T11/99-017v0 document. If, after fault isolation is performed by the host, it is determined that the incident is
because of a port failure, perform a data collection procedure for this switch using the EFC manager, and return
the CD to McDATA for analysis.
Event Data: Byte 0 = Port number (00-0F)
Bytes 4-7 = Elapsed millisecond tick count
Bytes 8-11 = Port state indicators
0x00 = Active
0x01 = OLIB
0x05 = LR1
0x06 = LR2
0x07 = LR3
0x09 = LF2
0x0A = LF1
0x0C = OL1A
0x0D = OL1C
0x0E = OL2
0x0F = OL3
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔