McDATA 3032 Switch User Manual


 
2
Task 7: Configure Management Server Password and Network Addresses
2-25
Installation Tasks
10. After successful POST completion, the LCD panel displays a
Welcome!! message and all front panel LEDs extinguish.
11. If a POST error or other malfunction occurs, go to MAP 0000: Start
MAP on page 3-6 to isolate the problem.
12. Press the left edge (PUSH label) of the LCD panel to disengage
the panel and expose the CD-RW drive.
13. Insert a blank rewritable CD into the CD-RW drive and close the
LCD panel.
Task 7: Configure Management Server Password and Network
Addresses
Verify the type of LAN installation with the customer’s network
administrator. If the management server or Fabricenter equipment
cabinet is installed on a dedicated LAN, network information does
not require change. Change the default password for the server’s
LCD panel
(if required by the customer), then go to Task 8: Configure Management
Server Information on page 2-30.
If the management server or Fabricenter equipment cabinet is
installed on a public LAN segment, the default password for the
server’s LCD panel and the following transmission control protocol
internet protocol (TCP/IP) network information must be changed to
conform to the customer’s LAN addressing scheme:
IP address.
•Subnet mask.
NOTE: At some customer installations, TCP/IP addresses for the
management server may be allocated automatically using dynamic host
configuration protocol (DHCP).