McDATA 3032 Switch User Manual


 
4
4-46
McDATA® Sphereon 3032 and 3232 Fabric Switches Installation and Service Manual
Repair Information
Set Offline State
To set the switch offline:
1. Notify the customer the switch is to be set offline. Ensure the
customer’s system administrator quiesces Fibre Channel frame
traffic through the switch and sets attached devices offline.
2. At the EFC Server, open the EFC Manager application. The
Product View displays.
3. Select the icon representing the switch to be set offline. The
Hardware View for the selected switch displays.
4. At the navigation control panel, select Set Online State from the
Maintenance menu. If the switch is online, the Set Online State
dialog box displays, indicating the state is ONLINE
.
5. Click Set Offline. A Warning dialog box displays, indicating the
switch is to be set offline.
6. Click OK. As the switch goes offline, inspect the Product Manager
application. The State field of the Status table displays OFFLINE.
Block and Unblock Ports
This section describes procedures to block or unblock the switch
ports. When a port is blocked, the port is automatically set offline.
When a port is unblocked, the port is automatically set online.
NOTE: When a port is blocked, the operation of an attached Fibre Channel
device is disrupted. Do not block a port unless directed to do so by a
procedural step or the next level of support.
Block a Port
To block a port:
1. Notify the customer the port is to be blocked. Ensure the
customer’s system administrator quiesces Fibre Channel frame
traffic through the port.