McDATA 3032 Switch User Manual


 
B
System Events (000 through 199)
B-3
Event Code Tables
System Events (000 through 199)
Event Code: 001
Message: System power-down
Severity: Informational
Explanation: Power to the switch was shut down, either with the main power switch or through loss of the ac source. This event
is distributed the next time the switch powers on, but the date and time of the event reflect the time the shutdown
occurred.
Action: No action required.
Event Data: No supplementary data included with this event.
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔
Event Code: 011
Message: Login Server database found to be invalid
Severity: Minor
Explanation: Following an IML, CTP hot-plug, CTP card failover, or LIC load, the Login Server database failed its validation. All
Fabric Services databases are initialized to an empty state resulting in an implicit Fabric logout of all attached
devices.
Action: Perform the data collection procedure for the switch using the EFC Manager, and return the CD to McDATA for
analysis.
Event Data: No supplementary data included with this event.
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔✔✔✔