McDATA 3032 Switch User Manual


 
3
3-72
McDATA® Sphereon 3032 and 3232 Fabric Switches Installation and Service Manual
Diagnostics
MAP 0600: Port Failure and Link Incident Analysis
This MAP describes fault isolation for small form factor pluggable
(SFP) transceivers and Fibre Channel link incidents. Failure
indicators include:
One or more amber LEDs on the Fibre Channel ports illuminate.
The amber emulated LED adjacent to a port graphic at the
Hardware View illuminates.
A blinking red and yellow diamond (failed FRU indicator) or
yellow triangle (attention indicator) appears at the alert panel of
the Product View or Hardware View.
An event code recorded at the Sphereon 3216/3232Event Log or
the SANpilot event log.
A port operational state message or a Failed message at the Port
Properties dialog box or SANpilot interface.
A link incident event code recorded at the console of an OSI
server attached to the switch reporting the problem.
A link incident message at the Link Incident Log or Port Properties.
1
Was an event code 080, 081, 506, 507, 508, 512, or 514, observed at
the Sphereon 3032/3232Event Log (EFC Server) or at the SANpilot
event log?
NO YES
Go to step 3.
2
Was an event code 581, 582, 583, 584, 585, or 586 observed at the
console of an OSI or FICON server attached to the switch reporting
the problem.?
YES NO
Go to step 4.
3
The following table lists event codes, brief explanations of the codes,
and associated steps that describe fault isolation procedures.