McDATA 3032 Switch User Manual


 
3
3-104
McDATA® Sphereon 3032 and 3232 Fabric Switches Installation and Service Manual
Diagnostics
Figure 3-48 Configure Fabric Parameters Dialog Box
d. At the Switch Priority field, select Principal, Never Principal, or
Default (the default setting is Default). Then click Activate.
e. Set the switch online (Set Online State on page 4-45)
Did the switch priority change solve the problem and did both
switches join through the ISL to form a fabric?
NO YES
The switches, associated ISL, and multiswitch fabric appear
operational.
Contact the next level of support.
21
switch E_Port segmented (at an operational switch) because a
response (hello timeout) to a verification check indicates an attached
switch is not operational.
a. Perform the data collection procedure at the operational switch
and return the CD to McDATA for analysis. This information may
assist in fault isolating the failed switch.
b. Go to MAP 0000: Start MAP on page 3-6 and perform fault
isolation for the failed switch.
Exit MAP.
22
As indicated by an event code 072, a switch E_Port is connected to
an unsupported switch or fabric element.