McDATA 3032 Switch User Manual


 
B
Fan Module Events (300 through 399)
B-27
Event Code Tables
Event Code: 304
Message: Fifth cooling fan propeller has failed
Severity: Major
Explanation: A fifth fan has failed. The remainder of the fans in the system are installed and operational. If present, the LED on
the associated fan module is turned off. The fan has either stopped or was removed.
Action: Replace the fan module immediately.
Event Data: Byte 0 = Failed fan number (1-6).
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔✔✔✔✔
Event Code: 305
Message: Sixth cooling fan propeller has failed
Severity: Major
Explanation: A sixth fan has failed. If present, the LED on the associated fan module is turned off. The fan has either stopped
or was removed.
Action: Replace the fan module immediately.
Event Data: Byte 0 = Failing fan number (1-6).
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔✔✔✔✔