3
3-86
McDATA® Sphereon 3032 and 3232 Fabric Switches Installation and Service Manual
Diagnostics
h. Ensure the Connection Policy radio buttons are compatible for
both switches.
i. Click Activate for each switch. The switch binding feature is
consistently enabled for both switches.
Did configuring the fabric and switch binding parameters solve the
problem?
NO YES
↓ The switch appears operational. Exit MAP.
Contact the next level of support. Exit MAP.
30
A port connection is not allowed because of a fabric binding
mismatch. Fabric membership lists must be compatible for both
fabric elements.
a. At the Fabrics View for each switch, click Fabrics and select
Fabric Binding. The first Fabric Binding dialog box displays.
b. Ensure the Enable Fabric Binding checkbox is enabled
(checked) for both switches.
c. At the first Fabric Binding dialog box, click Next. The second
Fabric Binding dialog box displays.