McDATA 3232 Switch User Manual


 
2
2-136
McDATA® Sphereon 3032 and 3232 Fabric Switches Installation and Service Manual
Installation Tasks
c. Ensure the Operational State field displays Online and the
Reason field displays N/A or is blank. If an ISL segmentation or
other problem is indicated, go to MAP 0000: Start MAP on
page 3-6 to isolate the problem. If no problems are indicated,
installation tasks are complete.
7. At the management server’s Product View, click the switch icon.
The Hardware View for the selected switch displays.
8. Click the port connector (leftmost port) to open the Port Properties
dialog box.
Figure 2-106 Port Properties Dialog Box
NOTE: If the Open Trunking feature is installed and additional item will
appear in the Port Properties dialog box, called Congested Threshold %. This
field displays the active congested threshold percentage currently configured
in the Configure Open Trunking dialog box.
9. Ensure the Link Incident field displays None and the Reason field
is blank. If an ISL segmentation or other problem is indicated, go
to MAP 0000: Start MAP on page 3-6 to isolate the problem. If no
problems are indicated, installation tasks are complete.