A-26
McDATA® Sphereon 3032 and 3232 Installation and Service Manual
Messages
Action Review the Switch Binding Membership List to determine if the
devices should be members.
Message Port cannot swap to itself.
Description Port addresses entered in the Swap Ports dialog box are the same.
Action Make sure that address in the first and second port address fields are
different.
Message Port diagnostics cannot be performed on an inactive port.
Description This displays when port diagnostics is run on a port in an inactive
state.
Action Run the diagnostics on an active port.
Message Port speeds cannot be configured at a higher rate than the
director/switch speed.
Description This displays when you configure a port to 2 GB/sec and the switch
speed is set to 1 Gb/sec.
Action Set the port speed to 1 Gb/sec in the Configure Ports dialog box.
Message Element Manager error <number>.
Description The switch Element Manager encountered an internal error and
cannot continue.
Action Report the problem to support personnel.
Message Element Manager instance is currently open.
Description A Element Manager window is currently open.
Action Informational message only.